The DS-KV6124-WBE1 is a Hikvision 6-Series villa door station with 4MP video, 150° viewing angle, Wi-Fi, PoE / 12V DC power, 2 lock outputs, and unlocking by PIN, card, Bluetooth, Hik-Connect app, indoor station, or relay unlock.
1. What you need
You will usually need:
| Item | Purpose |
|---|---|
| DS-KV6124-WBE1 door station | Front door / gate intercom |
| 12V DC power supply or PoE switch | Powers the unit |
| Network cable | For setup / PoE / LAN connection |
| Hik-Connect app | Mobile app setup |
| iVMS-4200 or SADP Tool | Activation and configuration |
| Electric strike / maglock / gate input | For unlock function |
| Optional indoor monitor | For local answering inside the house |
The unit supports PoE or 12V DC. If using Wi-Fi, you still need to power the unit with 12V DC or PoE during setup.
2. Mounting height
Recommended mounting height is generally 1.4m to 1.6m from ground level to camera height. Hikvision’s quick-start material shows this range for the 6-Series villa stations and notes the 150° horizontal view angle.
Best practical height:
1.5m from finished floor level is usually ideal.
Avoid mounting:
- Too low, where faces are cut off.
- Too high, where you only see the top of people’s heads.
- Facing direct afternoon sun.
- Where rain can run down the wall into the cable entry.
Use silicone around the cable entry area to reduce water ingress, as Hikvision’s installation material specifically recommends sealing the wiring area.
3. Power and network options
Option A — Best method: PoE
Use a PoE switch.
Wiring:
Router / Network Switch
|
PoE Switch
|
DS-KV6124-WBE1
This is the cleanest method because one CAT6 cable provides both data and power.
Option B — 12V DC + Wi-Fi
Use this where no network cable is available.
12V DC power supply → DS-KV6124-WBE1
Wi-Fi router → Wireless connection
This is convenient, but for gates and front doors, wired PoE is still more stable.
4. First activation
Method 1 — Using SADP Tool
- Connect the DS-KV6124-WBE1 to the same network as your computer.
- Open SADP Tool.
- Find the device in the list.
- It will likely show as Inactive.
- Tick the device.
- Create an admin password.
- Activate the device.
- Set the IP address.
Example:
Router IP: 192.168.1.1
Door station: 192.168.1.64
Subnet mask: 255.255.255.0
Gateway: 192.168.1.1
DNS: 8.8.8.8 or router IP
Method 2 — Using iVMS-4200
- Open iVMS-4200.
- Go to Device Management.
- Look under Online Devices.
- Select the DS-KV6124-WBE1.
- Click Activate.
- Set password.
- Modify network settings.
5. Basic web login
Once activated:
- Open a browser.
- Go to:
http://DEVICE-IP
Example:
http://192.168.1.64
- Login with the admin password.
- Check:
- Network settings
- Time settings
- Video settings
- Intercom settings
- Unlock settings
- Wi-Fi settings if needed
6. Wi-Fi setup
If using Wi-Fi:
- Login to the door station.
- Go to Network.
- Find Wi-Fi settings.
- Scan for Wi-Fi.
- Select the customer’s Wi-Fi network.
- Enter Wi-Fi password.
- Save.
- Confirm the unit receives a valid Wi-Fi IP address.
- Disconnect Ethernet only after Wi-Fi is confirmed working.
Important: make sure the Wi-Fi signal is strong at the front door or gate. If signal is weak, use PoE or install an outdoor access point.
7. Add to Hik-Connect app
- Open Hik-Connect.
- Login to the customer’s account.
- Tap +.
- Scan the QR code on the device or add by serial number.
- Enable Hik-Connect on the door station if needed.
- Enter the verification code.
- Add the device.
On the door station, make sure:
Platform Access / Hik-Connect: Enabled
Status: Online
If it says Offline, check:
- Gateway is correct.
- DNS is correct.
- Internet is working.
- Device time is correct.
- Router is not blocking it.
8. Relay / unlock wiring
The DS-KV6124-WBE1 supports 2 lock controls. Hikvision lists this model as supporting two locks and multiple unlocking methods including PIN, card, Bluetooth, Hik-Connect and indoor station unlock.
Typical relay terminals will be similar to:
COM
NO
NC
For electric strike — fail secure
Most electric strikes use NO + COM.
Power Supply +
|
Strike +
Strike -
|
Relay NO
Relay COM
|
Power Supply -
When the relay triggers, the circuit closes and the strike unlocks.
For magnetic lock — fail safe
Most maglocks use NC + COM.
Power Supply +
|
Maglock +
Maglock -
|
Relay NC
Relay COM
|
Power Supply -
When the relay triggers, it breaks power and the maglock releases.
For gate motor trigger
Most gate motors only need a dry contact input.
Use:
COM + NO
Wire those into the gate controller’s push button / open input terminals.
Do not send 12V into a gate input unless the gate manual specifically says to. Most gate inputs only want a momentary dry contact.
9. Configure unlock settings
In the device settings, check:
Access Control / Relay / Door Lock
Set:
Relay 1: Main door / gate
Unlock duration: 1 to 3 seconds for gate trigger
Unlock duration: 3 to 5 seconds for electric strike
Relay 2: Optional second lock
For a gate motor, usually use:
Unlock duration: 1 second
For an electric strike:
Unlock duration: 3 to 5 seconds
For a maglock:
Unlock duration: 5 seconds
10. Adding an indoor station
If using a Hikvision indoor monitor:
- Activate the indoor station.
- Put it on the same network.
- Set indoor station room number, commonly:
Room No: 101
- In the door station, set call destination to the indoor station.
- In iVMS-4200, add both devices.
- Link the door station to the indoor station.
- Press the call button and test.
Typical setup:
Door Station: 192.168.1.64
Indoor Station: 192.168.1.65
Room Number: 101
When someone presses the door station button, the indoor monitor should ring.
11. Adding to an NVR
You may also add the DS-KV6124-WBE1 to a Hikvision NVR as an IP camera stream.
On the NVR:
- Go to Camera Management.
- Add IP camera manually.
- Enter:
- IP address
- Username: admin
- Password
- Protocol: Hikvision
- Port: usually 8000
- Save.
- Confirm video appears.
This records the video stream, but it does not always give full intercom control from the NVR interface. Use Hik-Connect or indoor station for proper answering/unlocking.
12. Card / PIN / Bluetooth unlocking
The DS-KV6124-WBE1 supports multiple unlocking methods including card, PIN code, Bluetooth, Hik-Connect, and indoor station unlocking.
In the web interface or iVMS-4200:
- Go to Person / Access Control / User Management.
- Add user.
- Assign:
- PIN code
- Card number
- Bluetooth credential if supported in your firmware/app workflow
- Assign permission to Relay 1 or Relay 2.
- Test unlock.
13. Recommended basic settings
Use these as a practical default:
Device IP: Static
Time zone: Australia/Sydney
NTP: Enabled
Hik-Connect: Enabled
Video resolution: Main stream 4MP
Audio: Enabled
Echo cancellation: Enabled
Relay 1: Gate / front door
Unlock time: 1–5 seconds depending on lock type
Call destination: Hik-Connect and/or indoor station
14. Testing checklist
After setup, test these one by one:
| Test | Expected result |
|---|---|
| Press call button | Phone or indoor station rings |
| Answer call | Two-way audio works |
| Unlock from app | Relay clicks / gate opens |
| PIN unlock | Relay triggers |
| Card unlock | Relay triggers |
| Night image | Face is visible |
| Wi-Fi signal | Stable if using Wi-Fi |
| Reboot test | Device comes back online |
| Rain exposure | Cable entry sealed |
15. Common problems
Problem: Device not showing in SADP
Check:
- Laptop is on same network.
- Firewall is not blocking SADP.
- Network cable is working.
- PoE switch is powering the unit.
- Try direct connection to same switch.
Problem: Hik-Connect says offline
Check:
Gateway
DNS
Internet access
Platform Access enabled
Verification code
Device time
Use DNS:
8.8.8.8
1.1.1.1
Problem: Call button does not ring phone
Check:
- Hik-Connect is online.
- Push notifications allowed on phone.
- Device is shared to the correct Hik-Connect account.
- Call destination is configured.
- App is not in battery-sleep mode.
Problem: Unlock works in app but gate does not open
Check:
- Use COM + NO for gate input.
- Relay duration set to 1 second.
- Gate input is correct.
- Test the gate by briefly shorting the gate input terminals manually.
- Do not inject voltage into dry contact input.
Problem: Electric strike buzzes but does not unlock
Check:
- Strike voltage matches power supply.
- Power supply has enough current.
- Strike is not under door pressure.
- Use NO/COM for fail-secure strike.
- Increase unlock time to 5 seconds.
Problem: Maglock does not release
Check:
- Use NC/COM.
- Relay is breaking power, not adding power.
- Exit button and emergency break glass are wired correctly.
- Power supply is correctly sized.
16. Simple wiring example for a gate
DS-KV6124-WBE1 Relay 1
COM ---------------- Gate input COM
NO ---------------- Gate input OPEN / PB / START
Set relay time:
1 second
This mimics a push button.
17. Simple wiring example for electric strike
12V DC Power Supply +
|
|
Electric Strike +
Electric Strike -
|
DS-KV6124 NO
DS-KV6124 COM
|
12V DC Power Supply -
Set relay time:
3–5 seconds
My recommended setup
For most professional installs, I would do:
PoE to the DS-KV6124-WBE1
Static IP address
Hik-Connect enabled
Indoor station optional
Relay 1 for gate/door
Relay 2 spare or second lock
NVR recording added separately if required
Use PoE wherever possible. Wi-Fi is handy, but for intercoms and gates, wired network is much more reliable.