Product Overview
For property owners and installers looking to add a strong audible and visual response to an existing wired alarm system, the HiLook HA-ALARM-SIREN1 External Wired Sounder is a compact, purpose-built siren designed for external wall mounting. Featuring a 105dB output measured at 30cm, it produces a penetrating alert that carries well beyond the immediate installation point, drawing attention from surrounding areas. Built with an IP54-rated PC+ABS enclosure, the unit handles dust ingress and water splashing without compromise, making it suitable for mounting on exposed exterior walls in residential and commercial settings. Equipped with an independently configurable LED flash, the HA-ALARM-SIREN1 can deliver visual-only alerts or simultaneous sound and light depending on how the control panel is configured. It accepts 8 to 16VDC input, with 12VDC being the standard alarm panel output, and draws a maximum of just 70mA, keeping demands on the panel low. The slim 140mm x 134mm x 33mm profile allows for unobtrusive installation across a range of building surfaces.
Key Capabilities
105dB Siren Output
Measured at 30cm, the 105dB sound level is loud enough to be heard well beyond the immediate perimeter of most residential and light commercial properties, making it effective at drawing attention and deterring unauthorised access quickly.
Independent LED Flash Control
The LED flash indicator can be configured to operate separately from the siren. This allows installers to set visual-only alerts for certain zones or trigger both simultaneously, providing flexibility to match specific site requirements without additional hardware.
IP54 Outdoor Protection
The IP54 rating confirms the enclosure resists dust ingress and water splashing from any direction, making the HA-ALARM-SIREN1 appropriate for permanent external wall mounting in typical Australian outdoor conditions, including sheltered eaves and carport walls.
Low Current Draw
With a maximum current consumption of 70mA and a quiescent draw of just 45mA, this sounder places minimal load on the alarm panel’s auxiliary output, leaving ample capacity for additional devices on the same panel power supply.
Best For
- Residential Perimeter Alerting: The 105dB output and IP54 housing make this unit well suited to mounting on the front or rear external wall of a home, where audible and visual deterrence is needed when the panel triggers.
- Commercial Shopfronts and Offices: Businesses with existing 12V wired control panels can add the HA-ALARM-SIREN1 as an after-hours audible deterrent, configurable to sound, flash, or both depending on alarm zone.
- Garages, Sheds, and Outbuildings: The wide voltage input range of 8 to 16VDC and low power draw make this sounder straightforward to wire into secondary panel outputs covering detached structures.
- Alarm System Upgrades and Retrofits: Where an existing wired panel has a spare siren output, the HA-ALARM-SIREN1 slots in without requiring panel replacement or complex reconfiguration.
Why Choose the HA-ALARM-SIREN1
The HA-ALARM-SIREN1 stands apart from basic siren accessories through its independently configurable LED flash, which most entry-level sounders do not offer. Being able to separate the visual and audible outputs means installers can tailor the sounder’s behaviour to specific site needs, rather than accepting a fixed combined response. The IP54 enclosure confirmed on the specification sheet ensures the unit holds up in permanently exposed outdoor locations without relying on additional weatherproofing. The 105dB output at 30cm is strong for a unit drawing only 70mA maximum, meaning it does not require a high-capacity power supply to operate alongside other panel devices. At 140mm x 134mm x 33mm and 185g, it is compact enough to mount neatly without dominating the building facade. Available through Security Wholesalers, the HA-ALARM-SIREN1 is a practical, panel-agnostic addition to any 12V wired intrusion system.
Buyer Decision Tips
Buyer Tip: Confirm your alarm control panel has a dedicated siren output capable of supplying 12VDC before ordering. The HA-ALARM-SIREN1 requires a hardwired connection within the 8 to 16VDC range and is not compatible with wireless or RF-based alarm systems. Also verify that your panel’s auxiliary power output can support the additional 70mA maximum draw alongside any other connected devices such as keypads or detectors.
Key Features & Technical Specifications
| Model | HA-ALARM-SIREN1 |
| Sound Output | 105dB @ 30cm |
| LED Flash | Yes, independently configurable from siren output |
| Power Supply | 8 to 16VDC (typical 12VDC) |
| Current Consumption (Active) | Max 70mA |
| Current Consumption (Quiescent) | 45mA |
| IP Rating | IP54 |
| Operating Temperature | -20°C to +60°C |
| Humidity Range | 10% to 90% RH (non-condensing) |
| Enclosure Material | PC+ABS |
| Colour | Blue |
| Dimensions | 140mm x 134mm x 33mm |
| Weight | 185g |
Ideal Use Cases
External Home Walls
Mounting on a front or side exterior wall gives the 105dB siren maximum audible reach across the property boundary, while the IP54 enclosure withstands rain splashing and dust typical of exposed residential facades.
Commercial Shopfronts
The independently configurable LED flash allows retail or office premises to use a visual-only alert during business hours and full sound-and-flash after closing, without requiring additional hardware or panel outputs.
Garages and Detached Sheds
The wide 8 to 16VDC input range and low 70mA maximum draw make the HA-ALARM-SIREN1 easy to wire into a secondary panel output serving a detached outbuilding, without overloading the panel’s auxiliary supply.
Alarm System Retrofits
Where an existing wired alarm panel has a spare siren output, the HA-ALARM-SIREN1’s compact 140mm x 134mm footprint and straightforward wiring allow it to be added without structural modifications or panel upgrades.
Choosing the Right Model
- Choose this model if: You have an existing 12V wired alarm control panel with a spare siren output and need a low-current, IP54-rated external sounder with independently configurable LED flash and 105dB output.
- Choose a different model if: Your alarm system is wireless or RF-based, as this sounder requires a hardwired 8 to 16VDC connection and has no wireless communication capability. If you need a higher decibel output exceeding 105dB for a very large open site such as a warehouse yard, a larger commercial-grade sounder may be more appropriate.
FAQs
- Does the HA-ALARM-SIREN1 work with any brand of wired alarm control panel?
Yes. The HA-ALARM-SIREN1 accepts 8 to 16VDC input, which covers the standard 12VDC siren output used by the vast majority of wired alarm control panels regardless of brand. As long as your panel has a dedicated siren or auxiliary output within this voltage range, the sounder will operate correctly. - Can I use the LED flash without activating the siren?
Yes. The LED flash on the HA-ALARM-SIREN1 can be configured to operate independently from the siren, allowing visual-only alerts when required. This is useful in situations where a silent visual indicator is preferred, such as during staffed business hours, without replacing the unit or adding extra hardware. - Is the HA-ALARM-SIREN1 suitable for permanent outdoor installation?
Yes. The IP54-rated PC+ABS enclosure provides protection against dust ingress and water splashing from any direction. It is rated for an operating temperature range of -20°C to +60°C, covering Australian outdoor conditions across most climates. It is not rated for submersion and should be avoided in positions subject to direct, sustained water flow. - How much current does the sounder draw from the panel?
The HA-ALARM-SIREN1 draws a maximum of 70mA when active and 45mA in quiescent (standby) state. This is a low draw by sounder standards, meaning it can be connected alongside keypads, detectors, and other panel devices without placing excessive demand on most standard alarm panel power supplies. - What cable should I use to wire the HA-ALARM-SIREN1?
Standard 2-core alarm cable (typically 0.5mm or 0.75mm cross-section) used for siren runs is appropriate for this sounder. Cable run length should be calculated based on your panel’s output voltage and the maximum 70mA current draw to avoid excessive voltage drop at the sounder. Follow your panel manufacturer’s recommendations for maximum siren cable runs. - Where can I access the datasheet for the HA-ALARM-SIREN1?
The product datasheet is available via the Additional Information section below. The HA-ALARM-SIREN1 is part of the Security Wholesalers range, and technical support queries regarding compatibility with specific alarm panels can be directed to the Security Wholesalers team prior to purchase.
Additional Information