Hikvision AX PRO System Layout

This guide explains the normal cable path, equipment groups and buying checks for Hikvision AX PRO System Layout. Confirm the exact model manual before installation.

Wiring and cabling guide

Before installation

Confirm the exact equipment models, cable types, power capacity, distances and current manufacturer instructions before installation. Terminal names and ratings vary between products.

Main diagram

Hikvision AX PRO System LayoutSECURITY WHOLESALERSsecuritywholesalers.com.auHikvision AX PRO System LayoutALM-HIKVISION-AX-PRO-SYSTEM-8A9C95 | Revision 0.9PLANNING DIAGRAM - CONFIRM EQUIPMENT, CABLING AND CURRENT INSTRUCTIONSSECURITYWHOLESALERS.COM.AUC1 - Wireless detector path /C2 - Wireless contact path /C3 - Wireless siren path /C4 - Internet path / Ethernet orC5 - Notification path / InternetWireless PIRsInterior detectionWireless Alarm HubSystem controlRouter / InternetCloud pathWireless ContactsPerimeter detectionWireless SirenLocal warningMobile AppUsers and notificationsConnection numbers match the cable schedule below.Line labels identify every cable or path so colour is not the only indicator.Diagram ALM-HIKVISION-AX-PRO-SYSTEM-8A9C95
Hikvision AX PRO System Layout. Cable references C1, C2 and onward match the cable schedule and detailed wiring table below.

Simple cable buying list

Use this table to prepare a shopping list. It deliberately separates minimum conductors from the more practical cable to install on a new run.

Device or circuit What to buy Cores / size Before you order
Wireless PIR, reed/contact, keypad or siren No field cable Nothing to prewire for the radio path Confirm battery type, radio frequency/region, hub compatibility and coverage.
Hub to router Optional factory patch lead or solid-copper Cat5e/Cat6 4 twisted pairs / 8 conductors Buy only if using wired Ethernet; Wi-Fi-capable hubs may not require it.
Hub power Use the supplied power arrangement Do not substitute alarm cable for a mains lead A power point or fixed supply may require a licensed electrician.
Existing wired detector connected through a transmitter/input module 4-core full-copper alarm cable; 6-core if separate tamper/spares are wanted Nominal 0.5 mm2 is a practical conventional detector choice The transmitter/input manual determines contact type and resistor value.

Confirm existing cabling before purchasing

  1. Photograph the panel model, detector labels, keypad and siren before ordering.
  2. At both ends of every existing run, count the conductors and read any sheath marking. Do not infer cable type from colour.
  3. Measure the route, not the straight-line room distance, and allow enough length for entry into the cabinet and a service loop.
  4. For an existing zone, isolate it and have the fitted resistor value and panel programming checked before ordering replacements.
  5. Buy full-copper cable. Avoid CCA (copper-clad aluminium), speaker cable and flat telephone cable for alarm field wiring.
  6. Do not buy resistors until the panel model and supervision mode are known; kits may already include the correct values.

Equipment list

  • Wireless PIRs - Interior detection
  • Wireless Alarm Hub - System control
  • Router / Internet - Cloud path
  • Wireless Contacts - Perimeter detection
  • Wireless Siren - Local warning
  • Mobile App - Users and notifications

Cable schedule

Use the diagram reference to follow the same connection from the main diagram into the detailed explanation below.

Diagram ref From To Cable type Core count Power or data Maximum distance Purpose / important notes
C1 Wireless PIRs Wireless Alarm Hub Manufacturer radio No field cable across wireless path Data/control Not stated Wireless detector path
C2 Wireless Contacts Wireless Alarm Hub Manufacturer radio No field cable across wireless path Data/control Not stated Wireless contact path
C3 Wireless Alarm Hub Wireless Siren Manufacturer radio No field cable across wireless path Data/control Not stated Wireless siren path
C4 Wireless Alarm Hub Router / Internet Ethernet or Wi-Fi to model 4 twisted pairs / 8 conductors Data/control Not stated Internet path
C5 Router / Internet Mobile App Internet / mobile data No field cable across wireless path Data/control Not stated Notification path

No maximum distance is invented. Where the exact figure depends on Ethernet design, voltage drop, current draw or the selected device, the schedule tells the installer to confirm it.

What the wiring actually is

Match each C reference to the same label on the main diagram and cable schedule. The line name alone is not a complete cable specification, so this table explains the physical cable, conductor or pair use, what it carries and how it normally terminates.

Diagram ref Cable shown Physical path Cable construction Conductors or pairs What it carries Normal termination Confirm before installation
C1 Manufacturer radio Wireless PIRs to Wireless Alarm Hub No data cable spans the wireless path. Each radio, router or mobile endpoint still needs its specified local Ethernet and power connection. Radio link through free space; local device cables are documented separately. Network data over Wi-Fi, licensed/unlicensed point-to-point radio or public mobile/internet service. Aligned radios/antennas or the applicable router/cloud service. Line of sight, Fresnel clearance, channel/interference, mounting, surge/earthing, bandwidth, data allowance and failover.
C2 Manufacturer radio Wireless Contacts to Wireless Alarm Hub No data cable spans the wireless path. Each radio, router or mobile endpoint still needs its specified local Ethernet and power connection. Radio link through free space; local device cables are documented separately. Network data over Wi-Fi, licensed/unlicensed point-to-point radio or public mobile/internet service. Aligned radios/antennas or the applicable router/cloud service. Line of sight, Fresnel clearance, channel/interference, mounting, surge/earthing, bandwidth, data allowance and failover.
C3 Manufacturer radio Wireless Alarm Hub to Wireless Siren No data cable spans the wireless path. Each radio, router or mobile endpoint still needs its specified local Ethernet and power connection. Radio link through free space; local device cables are documented separately. Network data over Wi-Fi, licensed/unlicensed point-to-point radio or public mobile/internet service. Aligned radios/antennas or the applicable router/cloud service. Line of sight, Fresnel clearance, channel/interference, mounting, surge/earthing, bandwidth, data allowance and failover.
C4 Ethernet or Wi-Fi to model Wireless Alarm Hub to Router / Internet Solid-copper Cat5e or Cat6 balanced Ethernet cable; Cat6 is the normal new-install choice. Fibre may replace copper for distance or electrical isolation. Four twisted pairs / eight conductors, terminated consistently to T568A or T568B. Ethernet data only unless the named port is specifically documented as PoE. RJ45 network termination or the stated SFP/fibre interface. 90 m permanent link / 100 m channel for copper Ethernet, port role, VLAN and whether the port supplies PoE.
C5 Internet / mobile data Router / Internet to Mobile App No data cable spans the wireless path. Each radio, router or mobile endpoint still needs its specified local Ethernet and power connection. Radio link through free space; local device cables are documented separately. Network data over Wi-Fi, licensed/unlicensed point-to-point radio or public mobile/internet service. Aligned radios/antennas or the applicable router/cloud service. Line of sight, Fresnel clearance, channel/interference, mounting, surge/earthing, bandwidth, data allowance and failover.

What "security cable" means

Security cable is a trade description, not a complete specification. On these pages it means multicore, stranded, full-copper extra-low-voltage alarm/access cable. A common Australian product is described as 14/0.20, approximately 0.44 mm2 per conductor, or nominal 0.5 mm2. The installer must still specify core count, conductor area, copper construction, twist/shield requirement, jacket/environment rating and permitted route. It is not Cat5e/Cat6, mains cable, fire-rated cable or automatically suitable for lock power.

Cable description Typical use Important limitation
2-core stranded copper A simple unpowered contact, dry-contact trigger or separately designed DC power pair Not enough for a powered PIR that also needs an alarm-contact pair. For lock power, calculate conductor size from voltage, current, inrush and distance.
4-core stranded copper Common for one powered PIR: positive and negative supply plus two alarm-loop conductors; also used for some proprietary four-wire keypad/module buses Four cores do not define the function or resistor. Label both ends and follow the panel/device manual.
6-core or 8-core stranded copper Powered devices needing alarm, tamper, auxiliary functions or useful spare conductors Do not join spare conductors to increase current capacity unless the equipment/cable design explicitly allows it.
Twisted or shielded security/bus cable RS-485/OSDP and other buses only where the manufacturer specifies impedance, twist and shield treatment Ordinary alarm cable is not automatically a compliant RS-485, OSDP or Ethernet cable.
Heavier two-core lock/power cable Electric strikes, maglocks, sirens or other higher-current ELV loads Common 0.5 mm2 alarm cable may be too small. Select 1.0 mm2, 1.5 mm2 or another size only after a voltage-drop and inrush calculation.

Core colours are identification aids only; they do not create a universal positive, negative, zone, tamper or data standard.

Are any resistors required?

Circuit Resistor required? Where it belongs How to select it
Wireless detector path No field EOL resistor Not applicable The radio link is supervised by the platform. A wired input on a detector, transmitter or hybrid panel may still need the exact manufacturer's resistor network.
Hybrid/wired expansion input Model and programming dependent At the field end when the input is EOL supervised Use the exact expansion-module manual; do not borrow a value from Bosch, DSC, Ness, Hills or Paradox.

Never choose a resistor by cable colour or by the phrase "security cable". First identify the exact input, panel model and programmed supervision mode. An EOL resistor belongs at the end of the supervised circuit; placing it across the panel terminals defeats cable supervision.

Power requirements

Confirm the selected equipment's supply method, PoE class or DC input, total load and backup requirements before ordering. Keep lock power separate from data-path assumptions, calculate voltage drop for low-voltage loads, observe battery polarity and isolate any 230-240 VAC work to an appropriately licensed electrician.

How the wiring path works

Read the physical cable path first, then power, relay or I/O paths, network addressing and finally app or cloud registration. A device that appears offline may have a physical link, power, addressing or configuration fault; Wi-Fi and cloud registration should not be used to hide an incorrect LAN design.

Practical installation sequence

  1. Confirm every exact device model and current manual.
  2. Confirm cable types, routes, separation and distances.
  3. Check PoE or DC power capacity and site voltage drop.
  4. Mount and cable devices with power isolated.
  5. Test continuity, polarity and earth/surge arrangements where applicable.
  6. Power one subsystem at a time.
  7. Activate and address network devices.
  8. Configure relay, call or recording behaviour only after the physical path works.
  9. Test local operation, remote operation and failure modes separately.
  10. Record final models, IP addresses, cable IDs, settings and diagram revision.

Common mistakes

  • Assuming a port provides PoE without checking the port and total switch budget.
  • Confusing a recorder's isolated camera ports with its main LAN uplink.
  • Powering a lock from an unsuitable relay or supply.
  • Guessing normally-open, normally-closed, polarity or resistor details.
  • Ignoring voltage drop, surge exposure or power-failure behaviour.
  • Treating app setup as proof that the physical cabling is correct.

Troubleshooting

Symptom Likely cause Test Corrective action
Device has no power Incorrect supply method or exhausted PoE budget Check port status and measure only with the correct procedure Match the power source to the exact device manual
Device powers but is offline Wrong LAN path, addressing or activation state Confirm link lights, subnet, gateway and device state Correct physical LAN and addressing before cloud setup
System works locally but not remotely Internet, DNS, account or cloud registration issue Prove local operation first, then test WAN services Correct router or account configuration; do not recable a working local link
Relay or lock action fails Wrong contact logic, power path or load assumption Test relay and lock supply as separate subsystems Use the exact manual and suitable lock PSU; confirm egress requirements

Compatible products and categories

Exact product links above were confirmed on the current Security Wholesalers site on 2026-07-19. Category links are used when an exact active compatible product was not confirmed.

Related diagrams

Frequently asked questions

Can I buy cable using this guide?

Use the cable schedule and buying list to shortlist the cable, then confirm the exact equipment model, route, distance, environment and manufacturer requirements before ordering.

Can cable distance or power capacity be assumed from this drawing?

No. Confirm the selected devices, PoE budget, voltage drop, cable construction and current manufacturer instructions.

Where do terminal names and resistor values come from?

They must come from the exact current manual for the selected model. Do not transfer terminal names, polarity or resistor values from a similar product.

Can this replace the manufacturer manual?

No. It is a planning and support reference only and does not replace manufacturer instructions, licensed work, fire engineering, egress assessment or site commissioning.

Technical references

Manufacturer Document Revision Relevant pages Reference Accessed
Hikvision DS-PWA96-M-WE AX PRO Datasheet 2024-03-22 Wireless zones, network and power overview Official/source reference 2026-07-19

Diagram revision: 0.9. Confirm the exact current manual for the selected equipment before installation.

Australian installation and safety notice

General guide only. Confirm current manufacturer instructions and site requirements. Work involving 230-240 VAC must be completed by an appropriately licensed electrician. Fire-release interfaces, emergency exits and door locking require project-specific compliance assessment. Keep mains and ELV cabling appropriately separated, isolate power before work, observe battery polarity and calculate voltage drop for the real load and cable run.

We make product support and ordering easy! Reach out to our help team :)
Trade Customers: Log In or Register to Unlock Even Better Prices.

Save & Share Cart
Your Shopping Cart will be saved and you'll be given a link. You, or anyone with the link, can use it to retrieve your Cart at any time.
Back Save & Share Cart
Your Shopping Cart will be saved with Product pictures and information, and Cart Totals. Then send it to yourself, or a friend, with a link to retrieve it at any time.
Your cart email sent successfully :)