Product SKU: T8144
Product Overview
For installations where PoE infrastructure needs to operate in demanding physical environments, the AXIS T8144 Industrial Midspan delivers 60W Power over Ethernet from a compact, DIN rail or cabinet-mountable unit. Built to handle temperatures from -40 degrees C to 75 degrees C, this single-port midspan is designed for deployment in outdoor enclosures, industrial cabinets, remote sites, and locations where standard PoE switches or injectors would not survive. Featuring dual DC inputs accepting 20-60 V DC, the T8144 supports power redundancy to keep connected devices online even if one supply fails. It operates as a plug-and-play solution, enabling PoE delivery to non-PoE equipment such as 3G/4G routers, unmanaged switches, or wireless access points. Compatible with all Axis PoE devices, this midspan suits field technicians and systems integrators who need a dependable, industrial-rated power injection point at the edge of a network.
Key Capabilities
Industrial Temperature Range
Rated from -40 degrees C to 75 degrees C, the T8144 continues operating in extreme cold and heat where standard PoE injectors would fail. This makes it suitable for outdoor enclosures, rooftop cabinets, and unheated industrial spaces.
Dual DC Input for Redundancy
Two separate DC inputs accept 20-60 V DC, allowing dual power feeds to be connected simultaneously. If one power source fails, the second maintains operation without interruption, which is critical for surveillance cameras or network equipment in remote or unattended locations.
60W PoE Output
With 60W available on a single PoE port, the T8144 supports high-power Axis devices including PTZ cameras, multi-sensor units, and access control panels that exceed the 30W ceiling of standard PoE+ injectors.
DIN Rail and Cabinet Mounting
The T8144 is designed to mount on a standard DIN rail or inside an electrical cabinet, keeping industrial installations tidy and reducing the need for separate mounting hardware in structured enclosures.
Best For
- Harsh Environment Deployments: The -40 to 75 degrees C operating range makes this midspan appropriate for unheated enclosures, rooftop boxes, and industrial outdoor cabinets where ambient temperature cannot be controlled.
- Remote or Unattended Sites: Dual DC input power redundancy ensures connected cameras or network equipment stay powered if one supply fails, reducing the need for on-site intervention at remote locations.
- Adding PoE to Non-PoE Infrastructure: Where an existing switch, 3G/4G router, or Wi-Fi access point does not provide PoE, the T8144 inserts PoE into the data line without replacing the upstream equipment.
Why Choose the AXIS T8144
Consumer-grade PoE injectors are not built for the temperature extremes or power redundancy requirements common in industrial and outdoor surveillance installations. The AXIS T8144 addresses both concerns directly: a confirmed operating range of -40 to 75 degrees C and dual DC inputs accepting 20-60 V DC set it apart from desktop injectors that would fail or lack redundancy in the same environments. At 60W output, it also goes beyond the 30W ceiling of standard PoE+ devices, supporting higher-draw Axis equipment without additional hardware. The plug-and-play design means no configuration is required at the device level. For integrators specifying field enclosures, transit hubs, or infrastructure-critical installations, the T8144 is part of the Security Wholesalers range and represents a purpose-built solution rather than a workaround.
Buyer Decision Tips
Buyer Tip: Confirm that your DC power supply output falls within the 20-60 V DC input range before specifying this midspan. The T8144 does not accept AC mains power directly, so an appropriate DC power source or converter must be part of the installation design. If your site uses a standard 230V AC supply, a DC converter or PSU rated to this input range will be required upstream of the T8144.
Key Features & Technical Specifications
| Model | AXIS T8144 |
| Type | Industrial 1-port PoE Midspan |
| PoE Output | 60W |
| Number of Ports | 1 |
| DC Input Voltage | 20-60 V DC (dual input) |
| Power Redundancy | Yes, via dual DC inputs |
| Operating Temperature | -40 degrees C to 75 degrees C |
| Device Compatibility | All Axis PoE devices |
| Mounting Options | DIN rail, cabinet |
| Installation | Plug-and-play |
| Typical Use | Adding PoE to non-PoE switches, 3G/4G routers, Wi-Fi access points |
Ideal Use Cases
Outdoor Surveillance Enclosures
The industrial temperature range allows the T8144 to operate inside rooftop or pole-mounted enclosures exposed to summer heat or winter cold without a climate-controlled housing.
Remote Site Camera Power
At locations fed by DC supplies such as solar systems or 48V infrastructure, the 20-60 V DC dual input accepts these sources directly and maintains PoE delivery to cameras even if one feed is interrupted.
Non-PoE Router or Switch Upgrades
Where a 3G/4G router or unmanaged switch lacks PoE output, the T8144 inserts into the data line between the switch and the camera, adding PoE without requiring equipment replacement.
High-Power Axis Device Support
PTZ cameras and multi-sensor Axis units that draw beyond standard PoE+ limits are supported by the 60W output, making the T8144 appropriate for installations where device power requirements exceed 30W.
Choosing the Right Model
- Choose this model if: Your installation uses DC power in the 20-60 V range, requires operation across extreme temperatures, needs dual-supply redundancy, or involves adding PoE to an existing non-PoE network device in a single-port industrial deployment.
- Choose a different model if: You need multi-port PoE injection across several cameras from a single unit, or your infrastructure runs on standard 230V AC mains without a DC converter, in which case a multi-port PoE switch or AC-input injector would be more appropriate.
FAQs
- What is a midspan and how does the T8144 differ from a standard PoE injector?
A midspan sits between a network switch and a PoE-powered device, injecting power into the Ethernet cable without replacing the upstream switch. The AXIS T8144 is an industrial-grade midspan rated to -40 to 75 degrees C with dual DC inputs, which distinguishes it from consumer or office-grade injectors that lack temperature tolerance and redundancy features. - Can the T8144 be used in an outdoor enclosure during Australian summer conditions?
Yes. The confirmed operating range of up to 75 degrees C means the T8144 can operate inside enclosures that accumulate heat in direct sun, which is a common issue with standard PoE hardware mounted outdoors in Australian conditions. - Does the T8144 accept mains 230V AC power directly?
No. The T8144 accepts only DC input in the range of 20-60 V DC. If your site uses standard 230V AC mains, a separate DC power supply or converter rated to output within this range must be installed upstream of the T8144. - How does the dual DC input provide redundancy?
Both DC inputs can be connected to separate power sources simultaneously. If one supply fails or is interrupted, the second input continues to power the midspan and the connected PoE device without any manual intervention. This is particularly useful for unattended remote sites where power reliability cannot be guaranteed from a single source. - Is the T8144 compatible with non-Axis PoE devices?
The product data confirms compatibility with all Axis PoE devices. While the T8144 uses standard PoE protocols and may work with other brands, it is specified and tested for Axis equipment. For non-Axis deployments, compatibility should be verified against the connected device’s PoE standard requirements. The T8144 is available through Security Wholesalers for confirmed Axis-based installations.
Additional Information
{
“@context”: “https://schema.org”,
“@type”: “FAQPage”,
“mainEntity”: [
{
“@type”: “Question”,
“name”: “What is a midspan and how does the T8144 differ from a standard PoE injector?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “A midspan sits between a network switch and a PoE-powered device, injecting power into the Ethernet cable without replacing the upstream switch. The AXIS T8144 is an industrial-grade midspan rated to -40 to 75 degrees C with dual DC inputs, which distinguishes it from consumer or office-grade injectors that lack temperature tolerance and redundancy features.”
}
},
{
“@type”: “Question”,
“name”: “Can the T8144 be used in an outdoor enclosure during Australian summer conditions?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Yes. The confirmed operating range of up to 75 degrees C means the T8144 can operate inside enclosures that accumulate heat in direct sun, which is a common issue with standard PoE hardware mounted outdoors in Australian conditions.”
}
},
{
“@type”: “Question”,
“name”: “Does the T8144 accept mains 230V AC power directly?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “No. The T8144 accepts only DC input in the range of 20-60 V DC. If your site uses standard 230V AC mains, a separate DC power supply or converter rated to output within this range must be installed upstream of the T8144.”
}
},
{
“@type”: “Question”,
“name”: “How does the dual DC input provide redundancy?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Both DC inputs can be connected to separate power sources simultaneously. If one supply fails or is interrupted, the second input continues to power the midspan and the connected PoE device without any manual intervention. This is particularly useful for unattended remote sites where power reliability cannot be guaranteed from a single source.”
}
},
{
“@type”: “Question”,
“name”: “Is the T8144 compatible with non-Axis PoE devices?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The product data confirms compatibility with all Axis PoE devices. While the T8144 uses standard PoE protocols and may work with other brands, it is specified and tested for Axis equipment. For non-Axis deployments, compatibility should be verified against the connected device’s PoE standard requirements. The T8144 is available through Security Wholesalers for confirmed Axis-based installations.”
}
}
]
}