Product Overview
For facilities where emergency communication must work without fail in the harshest conditions, the 2N IP Safety Emergency Intercom Station is built to deliver. Flush-mounted into walls, columns, or emergency call point enclosures, this orange (RAL 2004) station is immediately visible in industrial, construction, tunnelling, and public infrastructure environments where rapid identification of a call point can be critical. Featuring an IP69K ingress rating and IK10 impact resistance, the aluminium chassis withstands high-pressure washdowns, extreme dust, and deliberate impact. The 10 W loudspeaker ensures voice clarity in high-ambient-noise environments, while dual built-in microphones provide full-duplex communication over SIP 2.0. An onboard audio loop test automatically monitors microphone and speaker function, reporting any fault without manual inspection. With an operating range of -40°C to 55°C and support for PoE 802.3af or 12 V DC power, the 2N IP Safety station suits demanding deployments where standard intercom hardware would not hold up.
Key Capabilities
IP69K and IK10 Protection
Rated IP69K for high-pressure, high-temperature washdowns and IK10 for resistance to heavy impact. The cast aluminium chassis is built for environments where standard IP-rated hardware would fail, including food processing areas, wash bays, and exposed industrial locations.
10 W Loudspeaker for Noisy Environments
The 10 W loudspeaker cuts through ambient noise common on factory floors, loading docks, and construction sites. Callers on both ends can communicate clearly without shouting or repeating, which matters in time-sensitive emergency situations.
Full-Duplex Audio with Dual Microphones
Two built-in microphones enable full-duplex voice communication, allowing both parties to speak and hear simultaneously without switching. Supported codecs include G.711, G.722, G.729, and L16/16 kHz, covering a range of network quality conditions.
Automatic Audio Loop Self-Test
The built-in audio loop test continuously monitors both the microphone and speaker for faults, reporting failures automatically. In safety-critical installations, this removes the need for regular manual testing to confirm the unit is fully operational.
SIP 2.0 with No Dedicated Server Required
Operating over SIP 2.0 (RFC-3261), the 2N IP Safety station integrates with existing IP telephony infrastructure or can function without a dedicated SIP server. It supports time profiles, tamper detection, and control of 2 electric locks directly from the unit.
Extreme Temperature Operating Range
Rated for operation between -40°C and 55°C, the 2N IP Safety station is suitable for outdoor installations in cold climate regions, unheated industrial buildings, and exposed sites where temperature swings are significant across seasons.
Best For
- Industrial Emergency Call Points: The IK10 impact rating and IP69K washdown resistance make this station suitable for heavy manufacturing facilities, chemical plants, and food processing environments where equipment is routinely exposed to water jets and physical force.
- Tunnels, Car Parks, and Infrastructure Sites: The orange RAL 2004 housing and blue backlit button provide immediate visual identification in low-light or high-traffic environments. The 10 W speaker carries over engine noise and ventilation systems.
- Cold Climate and Outdoor Installations: With an operating range starting at -40°C, the 2N IP Safety station remains functional in exposed outdoor locations and unheated structures where many intercoms would fail in winter.
- Safety-Critical Sites Requiring Fault Monitoring: The automatic audio loop test reports microphone and speaker faults without manual checks, suiting sites where compliance and functional verification of emergency equipment is required.
Why Choose the 2N IP Safety Emergency Intercom Station
Most IP intercom stations are designed for controlled indoor environments, with IP ratings that stop well short of what harsh industrial or outdoor sites demand. The 2N IP Safety station addresses that gap directly. The IP69K certification means the unit can withstand high-pressure, high-temperature water jets, not just rain splash. The IK10 impact rating means the cast aluminium housing resists deliberate or accidental blows. The 10 W speaker output is significantly higher than standard intercoms, providing the volume needed in areas with constant background noise. The onboard self-test capability is a practical advantage for safety compliance, removing the reliance on scheduled manual checks to confirm the unit is functioning. At -40°C minimum operating temperature, this is one of the few intercom stations suited to genuinely extreme cold. Available through Security Wholesalers, the 2N IP Safety station is a purpose-built emergency communication device for environments where standard hardware is not adequate.
Buyer Decision Tips
SIP Infrastructure Compatibility: The 2N IP Safety station operates over SIP 2.0 and can work without a dedicated SIP server, but it must connect to an IP network. Confirm that your site has an active Cat-5e or higher Ethernet run to each intended flush-mount location before specifying this unit. PoE 802.3af delivery from a compatible switch or injector is the simplest power approach, eliminating the need for a separate 12 V DC supply at each call point.
Flush Mount Recess Planning: The 2N IP Safety station requires a recessed back box or in-wall cavity. At approximately 216 mm high by 109 mm wide by 84 mm deep, the wall recess must accommodate the full housing depth before surface installation. For retrofit projects, verify available wall depth early in the design phase to avoid on-site modifications.
Key Features & Technical Specifications
| Product Type | Emergency IP Intercom Station (Flush Mount) |
| Speaker Output | 10 W loudspeaker |
| Microphones | Dual built-in microphones |
| Audio Mode | Full-duplex |
| Audio Codecs | G.711, G.722, G.729, L16/16 kHz |
| Signalling Protocol | SIP 2.0 (RFC-3261) |
| Supported Protocols | SIP 2.0, DHCP, SMTP, 802.1x, RTSP, RTP, TFTP, HTTP, HTTPS, Syslog |
| IP Rating | IP69K |
| IK Rating | IK10 |
| Power Input | PoE 802.3af Class 0 (max 12.95 W) or 12 V / 2 A DC |
| Network Interface | 10/100BASE-TX, Auto-MDIX, RJ-45 |
| Chassis Material | Cast aluminium |
| Colour | Orange (RAL 2004) with blue backlit buttons |
| Lock Control | Controls 2 electric locks; additional switch connection |
| Operating Temperature | -40°C to 55°C |
| Operating Humidity | 10% to 95% (non-condensing) |
| Dimensions (H x W x D) | 8.50″ x 4.30″ x 3.30″ (approx. 216 mm x 109 mm x 84 mm) |
| Warranty | 3-year limited |
| Country of Origin | Czech Republic |
Ideal Use Cases
Industrial Manufacturing Facilities
The IP69K rating allows the station to be installed in production areas subject to daily high-pressure water and chemical washdowns. The IK10 chassis resists impact from trolleys, forklifts, or accidental contact with heavy equipment.
Tunnels and Underground Infrastructure
The 10 W loudspeaker and dual microphones maintain clear two-way communication in tunnel environments where vehicle noise, ventilation systems, and reverb make standard audio hardware impractical. The orange housing is immediately visible along a tunnel wall.
Multi-Level Car Parks
Flush-mounted into concrete columns or stairwell walls, the 2N IP Safety station provides a durable emergency call point for car park users. The blue backlit button and orange colour aid identification in dimly lit parking structures.
Construction Sites and Temporary Facilities
The -40°C to 55°C operating range and IP69K protection make the 2N IP Safety station functional on exposed construction sites across all seasons. SIP 2.0 support allows integration into temporary site communication networks.
Safety-Regulated Worksites Requiring Fault Verification
Sites with WHS obligations around functional emergency communication equipment benefit from the automatic audio loop test, which reports microphone or speaker faults without manual verification checks, simplifying compliance documentation.
Choosing the Right Model
- Choose this model if: Your site requires an emergency intercom that can withstand high-pressure washdowns (IP69K), heavy physical impact (IK10), extreme temperatures down to -40°C, and needs a 10 W speaker to cut through significant ambient noise. The flush mount housing and orange colouring suit permanent installation at designated emergency call points.
- Choose a different model if: Your installation is in a controlled indoor environment such as an office lobby or reception area where IP69K and IK10 protection are unnecessary. A standard surface-mount IP intercom station with lower ingress and impact ratings would be a more cost-appropriate fit for those locations.
- Choose a different model if: You need video at the emergency call point. The 2N IP Safety station is an audio-only intercom device and does not include a camera. If visual verification of the caller is required, an IP video intercom with matching environmental ratings would be needed instead.
FAQs
- What does the IP69K rating mean for a flush-mounted intercom station?
IP69K is the highest ingress protection rating for water and dust. It certifies that the unit can withstand high-pressure, high-temperature water jets directed from multiple angles without water penetrating the housing. For the 2N IP Safety station, this means it can be installed in areas that are routinely hosed down or pressure-cleaned, including food processing areas, wash bays, and outdoor wall surfaces. - Does the 2N IP Safety station require a dedicated SIP server to operate?
No. The station supports SIP 2.0 (RFC-3261) and can operate without a dedicated SIP server. It can register with an existing IP-PBX or be configured for direct IP calling in simpler deployments. This provides flexibility for sites that do not have a managed telephony server on site. - How does the automatic audio loop test work?
The 2N IP Safety station includes a built-in self-test that actively monitors both the microphone and the speaker for faults. If either component fails or degrades, the system reports the fault automatically, without requiring a technician to visit the unit and manually test it. This is particularly valuable in safety-critical installations where the unit must be verifiably operational at all times. - Can the 2N IP Safety station control door locks or access points?
Yes. The station can control 2 electric locks directly, with an additional switch connection also available. This allows the emergency intercom to integrate with door release functions so that an operator answering the emergency call can also remotely unlock an access point for evacuation or rescue purposes. - What power options are available for the 2N IP Safety station?
The station supports 2 power inputs: PoE 802.3af (Class 0, up to 12.95 W) delivered over a Cat-5e or higher network cable, or a direct 12 V / 2 A DC supply. PoE is typically the simpler option in new installations as it eliminates the need for a separate power run to each call point location. - Is the 2N IP Safety station suitable for outdoor installation in cold climates?
Yes. The operating temperature range of -40°C to 55°C means the station functions in cold climate conditions that would render most standard intercoms inoperable. The cast aluminium chassis and IP69K rating also protect against moisture intrusion from condensation, rain, and snow when installed outdoors. - Where can I purchase the 2N IP Safety Emergency Intercom Station in Australia?
The 2N IP Safety station is available through Security Wholesalers, supplied as a single flush-mount unit including the station itself. Contact the team to confirm current stock, volume pricing, and compatibility with your existing SIP or IP telephony infrastructure before ordering.
Cabling Considerations
- Cable Type: Cat-5e or higher (Cat-6 recommended for new installations) for both network connectivity and PoE power delivery.
- Maximum Cable Run: Up to 100 m from the PoE switch or injector to the station for standard PoE 802.3af delivery. Runs exceeding 100 m will require a PoE extender or midspan injector at an intermediate point.
- PoE Considerations: The 2N IP Safety station is a PoE Class 0 device drawing up to 12.95 W. Confirm that the supplying switch port or injector provides at least 15.4 W output capacity to allow for cable loss and ensure stable operation.
- Lock Control Wiring: The station controls 2 electric locks via onboard relay outputs. Run low-voltage cable (typically 18 AWG or as specified by the lock manufacturer) from the station to each lock. Plan cable routing through the wall cavity during the flush-mount recess preparation stage to avoid surface-mounted conduit after installation.
- Wiring Tips: In industrial environments where the cable run passes near high-voltage conduit, variable frequency drives, or heavy machinery, use shielded Cat-6 or Cat-6A cabling to reduce electromagnetic interference. Terminate the shield at one end only (typically at the switch) to avoid ground loops.